Factorymation Spring 2025 Catalog
SEE INSIDE BACK COVER FOR MORE DETAILS www.factorymation.com/circuitprotection CIRCUIT PROTECTION 29 Locking Devices Removable Locking Device Fixed Plate Locking Device Mechanical Interlock Device Part Number Applicable MCCB Removable Locking Device PL0 UTE100 PL2 UTS150/250 PL3 UTS400/600 PL5 UTS800/1200 Fixed Plate Locking Device PHL0 UTE100 PHL2 UTS150/250 PHL3 UTS400/600 PHL5 UTS800/1200 Mechanical Interlock, Padlock not Included MIT03 UTE100 MIT23 UTS150/250 MIT33 UTS400/600 MIT53 UTS800/1200 Replacement Lugs Part Number Pack Qty. Applicable MCCB MCCB LUG-AL100TE 3 UTE100 MCCB LUG-AL150TS 3 UTS150 MCCB LUG-AL250TS 3 UTS250 MCCB LUG-AL400TS 3 UTS400 MCCB LUG-AL600TS 3 UTS600 MCCB LUG-AL800TS 3 UTS800 MCCB LUG-AL1200TS 3 UTS1200 Molded Case Circuit Breakers (cont’d) Shunt Trip Modules Undervoltage Trip Modules Switch Modules Auxiliary Switch (AX) Provides remote “On” and “Off” indication Alarm Switch (AL) Provides immediate indication of a breaker trip. Shunt and Undervoltage Trips (SHT) & (UVT) (SHT) - Opens breaker in response to externally applied voltage signal. (UVT) - Automatically trips when control voltage drops. Breaker cannot be closed again until voltage returns to 85% of control voltage. Part Number Applicable MCCB Side Contact Rating Configuration Auxiliary Switch Modules AX0-R UTE100 Left 5A @ 125VAC 3A @ 250VAC 0.4A @ 125VDC 0.2A @ 250VDC SPDT (1 N.O., 1 N.C.) AX0-T Right AX-AL0-T Right AX UTS150-600 - AX5 UTS800-1200 - Alarm Switch Modules AL0-R UTE100 Left 5A @ 125VAC 3A @ 250VAC 0.4A @ 125VDC 0.2A @ 250VDC SPDT (1 N.O., 1 N.C.) AL0-T Right AL UTS150-600 - AL5 UTS800-1200 - Part Number Control Voltage (Vn) Current Operating Voltage Applicable MCCB SHT0-12 12V AC/DC 30mA AC: 0.7-1.1Vn DC: 0.8-1.1Vn UTE100 SHT0-24 24V AC/DC 27mA SHT0-100 100-130V AC/DC 5.8mA SHT0-200 200-250V AC/DC 5.4mA SHT0-440 440-500V AC 3.5mA SHT-12 12V DC 30mA AC/DC: 0.7-1.1Vn UTS150 UTS250 UTS400 UTS600 SHT-24 24V AC/DC 24mA SHT-110 110-130V AC/DC 10.5mA SHT-220 220-240V AC, 250V DC 7.5mA SHT-380 380-500V AC 2.3mA SHT5-24 24-30V DC 5W Steady 200W Inrush 0.6-1.1 Vn UTS800 UTS1200 SHT5-100 100-130V AC/DC 0.56-1.1Vn SHT5-200 200-250V AC/DC SHT5-380 380-480V AC Part Number Control Voltage (Vn) Current Tripping Voltage Applicable MCCB UVT0-24 24V AC/DC 27mA 0.20–0.70Vn UTE100 UVT0-100 100-110V AC/DC 5.8mA UVT0-200 200-220V AC/DC 5.4mA UVT0-440 440-480V AC 3.5mA UVT-24 24V AC/DC 27mA 0.35–0.70Vn UTS150 UTS250 UTS400 UTS600 UVT-110 110-130V AC/DC 5.8mA UVT-220 220-240V AC, 250V DC 5.4mA UVT-440 440-480V AC 3.5mA UVT5-24 24-30V DC 5W Steady 200W Inrush 0.44–0.60Vn UTS800 UTS1200 UVT5-100 100-130V AC/DC UVT5-200 200-250V AC/DC UVT5-380 380-480V AC Internal Modules Module Options 149 1750 TOO LOW TO SHOW CALL OR GO ONLINE FOR PRICING $
Made with FlippingBook
RkJQdWJsaXNoZXIy NDU4NzI=