Factorymation Spring 2025 Catalog
To Order Call 1.800.972.0436 or Visit factorymation.com www.factorymation.com/motorcontrols MOTOR CONTROLS 82 Standard Contactors & Overloads (cont’d) Contactor Dimensions Contactor Dimension Legend in(mm) Contactor Frame Size H W D in mm in mm in mm 18A (AC) 3.189 81.0 1.772 45.0 3.362 85.4 18A (DC) 3.189 81.0 1.772 45.0 4.547 115.5 25A (AC) 3.189 81.0 1.772 45.0 3.425 87.0 25A (DC) 3.189 81.0 1.772 45.0 4.606 117.0 40A (AC) 3.524 89.5 2.165 55.5 3.852 97.9 40A (DC) 3.524 89.5 2.165 55.5 4.640 117.9 80A (AC/DC) 4.58 116.3 2.60 66.0 4.53 115.0 105A (AC/DC) 4.58 116.3 2.97 75.4 4.97 126.2 150A (AC/DC) 6.3 160.0 4.8 121.5 5.7 145.0 180A (AC/DC) 7.2 183.0 5.5 139.0 6.7 170.0 300A (AC/DC) 7.8 198.0 5.8 147.5 7.1 181.0 Overload Dimensions Overload H W D in mm in mm in mm IOL-25S 2.0 51.5 1.8 45 3.3 82.5 IOL-40S/-80S 3.0 76.0 2.0 50.0 4.2 106.0 IOL-105S 3.9 99.5 3.0 75.0 3.9 98.5 IOL-150L-097-LK IOL-150L-112-LK 4.6 116.4 3.0 75.0 4.2 106.2 IOL-150L-150-LK IOL-150L-215-LK 6.8 172.72 4.75 120.65 7.3 185.42 IOL-180L 6.8 172.72 4.75 120.65 7.3 185.42 IOL-300L 6.8 172.72 4.75 120.65 7.3 185.42 IOLE-40S 2.9 73.2 1.8 44.8 3.3 84.1 IOLE-105S 3.2 81.9 2.6 66 4.4 112 IOLE-420L 6.1 155 4.7 120 6.7 169.6 Overload Dimension Legend in(mm) D H W H D W H D ® Overload IOL-25S IOL-40S/80S IOL-105S/150L IOL-300L Number of Poles 3 Rated Operation & Insulation Voltage [V] 690 IEC 60947-4-1 1000 IEC 60947-4-1 [V] 600 UL; CSA Rated Impulse Voltage [kV] 6 8 Tripping Class 10 Phase Failure Sensitivity YES Current Direct YES NO Alternating [Hz] Up to 400 50/60 Ambient Temperature Storage -58 to 176°F (-50 to 80°C) Operating -4 to 158°F (-20 to 70°C) Pollution Degree 3 Current Heat Loss [W] 3 5.5 5.5 15 Weight [lb] 0.32 0.68 1.00/1.45 3.95 Shock Resistance [g/ms] 10/11 (IEC 60068-2-27; 1/2 Sine Wave) Standards IEC 60947-1 / 60947-4-1, UL 508; CSA C.22.2/14; VDE 0660/102 Power Terminals IP Rating IP10 IP00 Main Terminals Capacity Cross/Slotted Combination Allen Head Slide Bar Stranded / Solid (UL/CSA) 75°C, Cu Only [AWG] 14 - 6 18 - 2 8 - 1/0 8 - 1/0 Tightening Torque [lb-in] 20 35 53 141 (100-215A) 230 (200-420A) Overload Specifications Overload Accessories Part Number Price Description Separate Mount Block IHA-SMB-32F $7.85 For IOL-25S & IOLS-25S IHA-SMB-50F $10.55 For IOL-40S & IOLS-40S IHA-SMB-80F $10.55 For IOL-80S & IOLS-80S IHA-SMB-105F $13.15 For IOL-105L IHA-SMB-105S $26.90 For IOLE-105L Lug Terminals IHA-LUGS-215 $23.25 For IOL-300L-150 & IOL-300L-215, 3 pack IHA-LUGS-420 $48.60 For IOL-300L-310 & IOL-300L-420, 3 pack IHA-LUGSPCR $5.25 Spacers for IHA-LUGS-215 & IHA-LUGS-420 (required for UL) Lug Terminals Separate Mount Block Auxiliary Contact Ratings Rated Insulation Voltage (V) UL/CSA: 600, IEC/VDE 0660: 1000 Rated Operating Voltage (V) UL/CSA: 600, IEC/VDE 0660: 690 Rated Thermal Current (A) 20 Short Circuit Protection with Fuses IEC 60947-5-1 (A) 10 Min. Switching Capacity (V/mA) 17/5 Electrical Endurance (ops) 1 million Mechanical Endurance (ops) 10 million Non-Overlap Time (ms) 1.5 Insulation Resistance (MΩ) >10 Operational Voltage AC-15 110-127V 220-240V 380-400V 415-450V 500V 660-690V Rated Operating Current (A) 10 10 6 5 4 2 Pilot Duty Rating A600 Making Capacity (A) 250 Breaking Capacity (A) 250 Operational Voltage DC-13 24V 48V 110V 220V 440V - Rated Operating Current (A) 6 4 2 0.7 0.7 - Pilot Duty Rating P600 Making Capacity (A) 250 Breaking Capacity (A) 2 Auxiliary Contact Specifications
Made with FlippingBook
RkJQdWJsaXNoZXIy NDU4NzI=