Factorymation Spring 2024 Catalog

To Order Call 1.800.972.0436 or Visit factorymation.com www.factorymation.com/powersupplies POWER SUPPLIES 106 DIN Rail Power Supplies (cont’d) * Automatic recovery after fault condition removed General Specifications E328620 Part Number Price Output Power Output Voltage Voltage Adj. Range Output Current Nominal Input Voltage Single-phase 100-240VAC MDP24-24-1CBA $29.55 24W 24 VDC 24–28V 1A 90–264 VAC MDP34-24-1CBA $35.95 36W 24 VDC 24–28V 1.5A 90–264 VAC MDP60-24-1CBA $37.95 60W 24 VDC 24–28V 2.5A 90–264 VAC MDP75-24-1CBA $55.45 100W 24 VDC 24–28V 4.2A 90–264 VAC Low Profile, Class 2 24W to 100W Models: • Low Profile DIN rail mounting • Universal power input • Input noise filter • 60°C rating provides full power, no derating required • Short circuit, overvoltage and overload protection • Voltage stabilizer for inrush demands of industrial applications • DC ON green LED status indicator • UL/cUL/CE • 3 year warranty UL508 Model MDP-24-24-1CBA MDP-34-24-1CBA MDP-60-24-1CBA MDP-75-24-1CBA Input Voltage Range 90–264VAC Frequency Range 47–63 Hz Inrush Current 20/40A @ 115/230VAC 25/50A @ 115/230VAC 30/60A @ 115/230VAC 30/60A @ 115/230VAC Protection Overload* 120-160% 110-150% 110-150% 110-150% Over Voltage* 30-33VDC Short-Circuit* Hiccup Mode Current Limiting Fold Forward Current Limiting Fold Forward Current Limiting Fold Forward Current Limiting Environment Operating Temperature -40 to 159°F (-40 to 71°C) Humidity 20-95% RH Safety Standards UL Rating UL508, UL1310 Class 2, UL1604 Class 1, Div. 2 √ √ √ √ UL 1310 Class 2 √ √ √ √ Other Isolation 3000 VAC/4242VDC Isolation between Input and Output MTBF ≥848k hours ≥748k hours ≥662k hours ≥554k hours * Automatic recovery after fault condition removed General Specifications IP20 PROTECTION IP20 PROTECTION YR WARRANTY 3 YR WARRANTY 3 FROM $ 29.55 FROM $ 29.45 Part Number Price Output Power Output Voltage Voltage Adj. Range Output Current Nominal Input Voltage Single-phase 100-240VAC MDP18-12A-1C $30.50 18W 12 VDC 10.8–13.8V 1.5A 100–240 VAC MD18-24-1NB-P $29.45 18W 24 VDC 21.6–26.4V 0.75A 100–240 VAC MD30-5-1NB-P $33.55 30W 5 VDC 4.75–5.5V 6A 100–240 VAC MDP30-12A-1C $33.55 30W 12 VDC 12–14V 2.5A 100–240 VAC MD40-24-1NB-P $31.55 40W 24 VDC 21.6–26.4V 1.7A 100–240 VAC MDP50-12-1 $43.35 50W 12 VDC 10–14V 4.2A 100–240 VAC MDP60-12A-1C $59.40 60W 12 VDC 12–14V 5A 100–240 VAC MD60-24-1NB-P $58.65 60W 24 VDC 21.6–26.4V 2.5A 100–240 VAC MDP100-12A-1C $83.60 100W 12 VDC 11.4–14.5V 8.4A 100–240 VAC MD96-24-1NB-P $74.80 96W 24 VDC 21.6–26.4V 4A 100–240 VAC Two-phase 400-500VAC MDP100-24-2C $91.05 100W 24 VDC 22.5–28.5V 4.2A 400–500 VAC Compact Plastic Case Model MDP-18-12A-1C MD18-24-1NB-P MD30-5-1NB-P MDP30-12A-1C MD40-24-1NB-P MDP-50-12-1 MDP60-12A-1C MD60-24-1NB-P MDP100-12A-1C MD96-24-1NB-P MDP-100-24-2C Voltage Range 90-264VAC 85–264 VAC 85–264 VAC 85-264VAC 85-264VAC 100-240VAC 85-264VAC 85-264VAC 90-264VAC 85-264VAC 340-575VAC Frequency 47–63 Hz Inrush Current Typ. <10A @ 120VAC 35A/115VAC 70A/230VAC 30A/115VAC 60A/230VAC Typ. <20A @ 120VAC 30A/115VAC 60A/230VAC Typ. <25A @ 120VAC Typ. <20A @ 120VAC 30A/115VAC 60A/230VAC Typ. <30A @ 120VAC 30A/115VAC 60A/230VAC Typ. <10A @ 400/500VAC Overload Protection* 110-140% 105-150% 105-150% 110-140% 105-150% 105-150% 110-150% 105-150% 110-140% 105-150% 115-135% Over Voltage Protection* 125-145% 27.6-32.4V 6.25-7.25V 120-136% 31.2-36V 105-150% 120-136% 31.2-36V 121-145% 12V: 15.6-18V 24V: 31.2-36V 125-138% Short-Circuit Protection* Hiccup Mode Current Limiting Fold Forward Current Limiting Hiccup Mode Current Limiting Fold Forward Current Limiting Hiccup Mode Current Limiting Fold Forward Current Limiting Hiccup Mode Current Limiting Operating Temperature -4 to 159°F (-20 to 71°C) -4 to 140°F (-20 to 60°C) -4 to 140°F (-20 to 60°C) -40 to 159°F (-40 to 71°C) -4 to 140°F (-20 to 60°C) 14 to 158°F (-10 to 70°C) -40 to 159°F (-40 to 71°C) -4 to 140°F (-20 to 60°C) -31 to 159°F (-35 to 71°C) -4 to 140°F (-20 to 60°C) -40 to 159°F (-40 to 71°C) Humidity 20-95% RH 5 to 90% RH 20-95% RH UL Rating UL508, UL60950-1, File #328620 Class 1, Div. 2 √ √ √ √ UL 1310 Class √ √ √ √ √ √ √ √ Isolation 3000 VAC/4242VDC Isolation between Input and Output 18W to 100W Models: • DIN rail mounting • Universal power input • Short circuit, overvoltage and overload protection • Voltage stabilizer for inrush demands of industrial applications • DC ON green LED status indicator • UL/cUL/CE

RkJQdWJsaXNoZXIy NDU4NzI=