Factorymation Spring 2024 Catalog

SEE INSIDE BACK COVER FOR MORE DETAILS www.factorymation.com/relays-timers RELAYS & TIMERS 151 Voltage, Current, and Phase Monitoring Relays Output green LED red LED Hysteresis Hysteresis Umin Umax t t Un 15 16 18 A1 A2 Un HRN-33 HRN-37 HRN-67 + 15 16 18 A1 A2 Un HRN-35 15 16 18 A1 A2 Un HRN-34 HRN-64 25 26 28 Part Number Monitored Voltage (Un) Sensing Range Contact Rating Contacts Time Range HRN-33 48-276VAC / 50/60Hz Upper (Umax): 160-276VAC Lower (Umin): 30-95%Umax 16A@250VAC 16A@24VDC SPDT 0-10 sec. HRN-34 6-30VDC Upper (Umax): 18-30VDC Lower (Umin): 35-95%Umax 16A@250VAC 16A@24VDC SPDT 0-10 sec. HRN-35 48-276VAC/ 50/60Hz Upper (Umax): 160-276VAC Lower (Umin): 30-95%Umax 16A@250VAC 16A@24VDC SPDT (x2) 0-10 sec. HRN-37 24-150VAC / 50/60Hz Upper (Umax): 80-150VAC Lower (Umin): 30-95%Umax 16A@250VAC 16A@24VDC SPDT 0-10 sec. HRN-64 6-30VDC Upper (Umax): 18-30VDC Lower (Umin): 35-95%Umax 16A@250VAC 16A@24VDC SPDT 0-10 sec. HRN-67 24-150VAC / 50/60Hz Upper (Umax): 80-150VAC Lower (Umin): 30-95%Umax 16A@250VAC 16A@24VDC SPDT 0-10 sec. HRN Series Voltage Sensing Relays 3-Phase Monitor Relays Wiring Dimensions in(mm) Features: • Monitors single-phase voltage for over / under voltage • Powered by monitored source • Time Delay setting (0-10 sec) • Max power consumption, 1.2VA • 16A Contact Rating, SPDT (DPDT available on HRN-35) • LED status indicators • Slim DIN rail mount, saves panel space • Operating Temp: -4° to 131°F (-20° to 55°C) 1.38(35) 3.54 (90) 1 18 (30) 2.66 (67.5) 1.77 (45) L1 L2 L3 Output U U off U U t1 t2 green LED red LED Hysteresis t1 t1 t1 min off off L2 L3 t1 Features: • Monitors voltage level and phase sequence • Powered by monitored source • LED status indicators • 8A Contact Rating, SPDT • Max power consumption, 2VA • Monitored voltage 50/60Hz • DIN rail mount • Standard Single Module Width (HRN-56-208 and HRN-56-240) • Standard Triple Module Width (HRN-56-480 and HRN-56-575) • Operating Temp: -4° to 131°F (-20° to 55°C) Un = Nominal voltage (rated voltage) Umin = The minimum acceptable voltage for normal operation (adjustable range: 70-95% of Un) Uoff = 60% of Un (fixed) Hysteresis = 5% of Un (fixed) t1 = 0.5 seconds (fixed) t2 = 0 - 10 seconds (adjustable) L2 L3 L1 18 L1 L2 L3 15 16 L2 L3 L1 18 15 16 18 15 16 HRN-56-208 HRN-56-240 HRN-56-480 HRN-56-575 Part Number Monitored Line Voltage Contact Rating Time Range Contacts HRN-56-208 3 x 208VAC Umin 70-95% Un : Uoff 60% Un 8A@250VAC 8A@24VDC 0 - 10 s SPDT HRN-56-240 3 x 240VAC Umin 70-95% Un : Uoff 60% Un 8A@250VAC 8A@24VDC 0 - 10 s SPDT HRN-56-480 3 x 480VAC Umin 70-95% Un : Uoff 60% Un 8A@250VAC 8A@24VDC 0 - 10 s SPDT HRN-56-575 3 x 575VAC Umin 70-95% Un : Uoff 60% Un 8A@250VAC 8A@24VDC 0 - 10 s SPDT Wiring Dimensions in(mm) 1.38(35) 3.54 (90) 1.18 (30) 1.89 (48) 2.52 (64) 2.66 (67.5) 1.77 (45) 0.69 (17.6) 2.05 (52) MODULAR DESIGN MODULAR DESIGN 1 6 AMP 8 AMP TOO LOW TO SHOW $ TOO LOW TO SHOW CALL OR GO ONLINE FOR PRICING $ TOO LOW TO SHOW $ E308660 E308660

RkJQdWJsaXNoZXIy NDU4NzI=