Factorymation Spring 2024 Catalog

www.factorymation.com/softstarters SOFT STARTERS 201 Wiring RL3C RL3NO DI1 COM 24V RL3NC DI2 DI3 R/1 L1 110 - 240VAC (-15% to +10%) 140mA Max. Start Stop PE U/1 T1 W/6 T3 V/4 T2 fuses L1 L2 L3 T/5 L3 S/3 L2 M Isolated Programmable Digital Inputs 110 - 240VAC 2mA Max. 220-575VAC 50/60Hz 0V DI4 DI5 RL1C RL1NO RL2C RL2NO Power Source Voltage 220 to 575 VAC Power Source Frequency 50 / 60 Hz (+/- 10%) or 45 - 66 Hz ) Control Voltage 110 to 240VAC (-15% to +10%), or 94 to 264 VAC Enclosure Plastic; IP20 in models from 17 to 85A Control Method Voltage variation over the load (three-phase induction motor) Starting Duty Cycle (10 Starts / Hr) 300% (3 x I nom ) during 30s (6 starts per hour) [Requires Ventilation Kit for Sizes 45A to 200A] Inputs (Digital) 5 Isolated Programmable Inputs Relay Outputs 3 relays, 240VAC, 2A, programmable functions Communication (Programmng) USB Safety / Protections Programmable overvoltage, undervoltage, voltage imbalance, phase sequence, motor overload, motor underload, overcurrent, undercurrent, current imbalance, undertorque, overtorque, underpower, overpower, input short-circuit, bypass overcurrent, bypass undercurrent, bypass failure, communication faults, Motor PTC overtemperature (with optional accessory) Standard Features Kick start, DC braking with contactor, optimal braking without contactor, reverse braking, fire mode, fault logging, parameter copying via keypad, real time clock (RTC), SoftPLC (ladder programming), 2 expansion slots Programming Commands On, Off / Reset, Jog, Parameterization (function Programming), and Parameter Help Ambient Temperature 32 - 131°F (-10 - 55°C) Standard Operation at Rated Current for Models up to 412A capacity 32 - 104°F (-10 - 40°C) Standard Operation at Rated Current for Models over 412A capacity Humidity 0 - 90%, Non Condensing Altitude 0 - 1000 m (3,300 ft) Standard Operation at Rated Current General Specifications Power Source Voltage 220 to 575 VAC Power Source Frequency 50 / 60 Hz (+/- 10%) or 45 - 66 Hz ) Control Voltage 110 to 240VAC (-15% to +10%), or 94 to 264 VAC Enclosure Plastic; IP20 in models from 17 to 85A Control Method Voltage variation over the load (three-phase induction motor) Starting Duty Cycle (10 Starts / Hr) 300% (3 x I nom ) during 30s (10 starts per hour) [Requires Ventilation Kit for Sizes 45A to 200A] Inputs (Digital) 3 Isolated Programmable Inputs Relay Outputs 2 relays with NO contacts, 240VAC, 1A, programmable functions Communication (Serial) RS-232 Safety / Protections Undercurrent, Programming Error, Current Imbalance, Serial Communication Error, Subcurrent Before Bypass, MMI Communication Error, External Defects, Overtemperature in Motor PTC, Locked Rotor, Excess Starting Time, Frequency Outside Tolerance, By-Pass Contact Open, Undervoltage in Control Supply, Motor Overload (class 5 to 30) Standard Features Voltage Ramp (Initial Voltage: 30% to 90%), Current Limitation (150% to 450% of SSW07 Rated Current), Starting Time (1 to 40s), Kick Start (Off - 0.2 to 2 sec), Deceleration Ramp (0 to 40s), Motor and Current Relation (50% to 100%), Faults Auto Reset, Thermal Memory Auto Reset, Factory Standard Reset, Soft Starter Built-In By-Pass Programming Commands On, Off / Reset and Parameterization (function Programming) Display Readings Motor Current (%Soft-Starter In), Soft-Starter Status, Motor Current (%Motor In), Digital Input and Output Status, Motor Current (A), Back Up of 4 Last Errors, Current Indication in each Phase R-S-T, Soft-Starter Software Version, Supply Network Frequency, Heatsink Temperature, Apparent Power Supplied to Load (kVA), Motor Thermal Protection Status Ambient Temperature 32 - 131°F (0 - 55°C) Standard Operation at Rated Current Humidity 0 - 90%, Non Condensing Altitude 0 - 1000 m (3,300 ft) Standard Operation at Rated Current Standards UL 508 Standard – Industrial Control Equipment, File# E198842 General Specifications Wiring 14/23 13 DI1 A2 A1 24 DI2 DI3 R/1 L1 L N 110 - 240VAC (-15% to +10%) 140mA Max. Start Stop PE U/1 T1 W/6 T3 V/4 T2 fuses L1 L2 L3 T/5 L3 S/3 L2 M Isolated Programmable Digital Inputs 110 - 240VAC 2mA Max. 220-575VAC 50/60Hz SSW07 Series Specifications SSW900 Series Specifications SEE INSIDE BACK COVER FOR MORE DETAILS

RkJQdWJsaXNoZXIy NDU4NzI=