To Order Call 1.800.972.0436 or Visit factorymation.com www.factorymation.com/acdrives AC DRIVES 6 TD400 Series AC Drives (cont’d) Connection Diagram P BR 3Ø Induction motor +10V: Max. 20mA AI1: Multi-Function Analog Input AI2: Multi-Function Analog Input S1 AO AGND Analog Output 0–10 VDC S2 S3 S4 S5 Multi-Functional Digital Inputs (Default Settings) Preset Speed 3 Preset Speed 2 Preset Speed 1 FWD / STOP REV / STOP Braking Connection COM (NPN) AGND: Analog Signal Common (R1A) (R1C) (R1B) NC NO Multi-function Relay Output Contact rating: • 250VAC < 1.0A • 30VDC < 1.0A R2A R2B S6 Reset +24V (PNP) NO SF1/SF2 SG Functional Safety Input (STO) RS485 COM1 RJ45 1:RS485+ 2:RS485- 7:5V 8:GND Shielded wire Control circuit Main circuit Note: 1 AC Line Reactor Circuit Protection AC Input Voltage Note: 3 Note: 2 AI1 AV1 JP2 Note: 4 AI2 AV2 JP3 Note: 5 External Analog Inputs Disconnect NPN PNP JP1 Note: 3 L1(L) L2 L3(N) U/T1 V/T2 W/T3 0 – 10V or 0 – 20mA Potentiometer: 2kΩ – 10kΩ Note: 6 S- S+ S+:RS485+ S-:RS485- Terminal 1 2 7 8 Notes: 1: Only 240V 0.5-25HP and 480V 1-40HP have a built-in braking transistor. The braking resistor can be connected directly to drive. All others drives require braking unit and resistor. 2: Functional Safety Input SF and SG should be a normally closed input. This input should be closed to enable the AC Drive output. A jumper is placed between SF and SG from the factory. 3: Use jumper JP1 to select between Sink (NPN, with –24V common, factory default) or Source (PNP, with +24V common) for multi-function digital input terminals S1–S6. 4: Use jumper JP2 to switch between voltage and current input for Multi-function analog input 1 (AI1). 5: Use jumper JP3 to switch between voltage and current input for Multi-function analog input 2 (AI2). 6: Ground must be less than 100Ω impedance. Greater than 100Ω indicates a poor ground. ® 5 BUILT-IN PLC FUNCTIONALITY Powerful control with an easy-to-program interface. Up to 80 rungs of ladder logic can be stored in PLC program. CONTROL Stop/start, change motor direction, and change speed of the AC drive. LIVE MONITORING Show present status, output levels, and any active faults of the AC drive. COMPARE FUNCTION Allows for easy review of changes made to parameters before writing program to AC drive. PARAMETER OPTIONS Write individual parameters to the drive or write the entire group. FULLY CUSTOMIZABLE GRAPHING Plot up to 4 data points in real-time. Export graph data to file for review later or to send to a client. 3 4 2 1 1 3 4 5 2 Power Supply Rated Input Power 240V Class – 200 to 240V, +10% / -15% 480V Class – 380 to 480V, +10% / -15% Output Characteristics Output Voltage Range 230V: 0–240V, 3-Phase 460V: 0–480V, 3-Phase Rated Output Frequency 0–599Hz Output Frequency Accuracy 0.01Hz Control Characteristics Control Mode Sensorless Vector, V/Hz, PMSLV Carrier Frequency 1 to 16kHz Frequency Control Range 0.01–599.00Hz Speed Control Accuracy V/Hz: +/- 2% Sensorless Vector: +/- 0.5% Overload Capacity 150% Rated Output Current for 60 sec. Frequency Setting Signal 0-10VDC, 4-20mA Accel/Decel Time 0–3600 sec. (Independent Accel/Decel Times) Number of V/F Patterns 30 Preset V/F Patterns, 2 Custom V/F Pattern Braking Torque Approximately 20% Protective Functions Stall Prevention, Instantaneous Overcurrent (200%), Motor Overload Protection, Overvoltage, Undervoltage, Momentary Power Loss, Overheat Protection, Ground Fault Environmental Conditions Location Indoor (IP20), UL Type 1 w/ optional conduit box Ambient Temperature 14 to 122°F (-10 to 50°C) Storage Temperature -4 to 158°F (-15 to 70°C) Altitude <1000m Humidity <95% RH (Non-condensing) Vibration 20HP and less: 9.8m/s 2 (1.0G) 25HP and more: 5.8m/s 2 (0.6G) Agency Approvals UL/cUL File# E503131, RoHS, CE 61800-3, IEC 60018-2-78 General Specifications Available for FREE download at www.factorymation.com/tdlink
Made with FlippingBook
RkJQdWJsaXNoZXIy NDU4NzI=