Factorymation Spring 2024 Catalog

SEE INSIDE BACK COVER FOR MORE DETAILS www.factorymation.com/motorcontrols MOTOR CONTROLS 73 IMM Terminal Specifications 32 Amp Frame 16 Amp Frame 65 Amp Frame General Specifications General Specifications IMM16 IMM32 IMM65 Standards IEC 60947-1/60947-4-1, EN 60947-1 / EN 60947-4-1, UL508, CSA C.22.2/14 Rated Insulation (Ui) & Operating (Ue) Voltage [V] UL/CSA: 600V, IEC 60947-1: 690V Rated Impulse Voltage Acc. IEC60947-1 [kV] 6 Rated Operating Frequency [Hz] 50/60 Overvoltage Category III Phase Failure Sensitivity Protection Yes Overload Protection Characteristics (x lu) [A] 0.61 to 1 Magnetic Release (x lu) [A] 13 Overload Trip Class 10 Total Power Loss Pv At Rated Load Operating Temp [W] 6 6 (1.6A to 16A) / 8 (20A to 40A) 25 Utilization Category IEC 60947-2 (Motor Protector) A IEC 60947-4-1 (Motor Starter) AC-3 Lifespan Mechanical: 100,000 ops., Electrical (le max.): 100,000 ops., Switching Rate (motor start) AC-3: 15 ops/hr Degree of Protection IP20 Resistance Shock resistance: 15g/11ms, Vibration resistance: 10g/5 - 150Hz Screw Driver Philips #2 Philips #2 Allen #4 Terminal Capacity Solid - Stranded 1 or 2 conductors (18 to 12 AWG) (see IMM Terminal Specs ) (see IMM Terminal Specs ) Tightening Torque [lb-in] 11 to 16 lb-in (1.2 to 1.7 Nm) 18 to 22 lb-in (2.0 to 2.5 Nm) 55 lb-in (6.2 Nm) Environmental Conditions Ambient Temperature Storage: -58 to 176°F (-50 to 80°C), Operating: -4 to 140°F (-20 to 60°C) Climatic Proofing IEC 60068-2-3 / IEC 60068-2-30 Altitude (Up to 6,600ft) Altitude (Up to 6,600ft): Nominal values, Pollution degree: 3, Mounting position: Any Weight [lb] 0.7 0.7 1.42 Warranty 1 year A B 1 Conductor on Lower Part Only 2 Conductors, 1 on Upper Part (A) and 1 on Lower Part (B) 12 to 2 AWG 16 to 2 AWG 16 to 2 AWG 12 to 2 AWG 12 to 2 AWG 16 to 2 AWG 16 to 2 AWG 12 to 2 AWG 8 to 2 AWG 14 to 2 AWG 14 to 2 AWG 8 to 2 AWG 55 lb-in (6.2 Nm) Manual Motor Protectors (cont’d) A B Drawing (mm 2 ) (AWG) 1 or 2 x (1 to 2.5) 1 or 2 x (2.5 to 6) - - 1 or 2 x (14 to 10) 1 x (8) 1 or 2 x (1 to 2.5) 1 or 2 x (2.5 to 6) 1 x (10) 1 or 2 x (14 to 10) 10 Terminal Capacity IMM16/IMM32 Terminal Capacity IMM65 Solid Ferrule Stranded Tightening Torque Trip Characteristics Tripping time as function of the current at cold condition. For warm condition (after submitted to the rated operational current - Ie ), the tripping times reduce to approximately 25%. The characteristics of the magnetic trip are based on the upper value of the setting range for IMM16, IMM32 & IMM65. Average Curves Curve 1: 3 pole Curve 2: Bipolar with phase loss sensitivity E-Handle Type A Min–Max Inches (mm) MMS Type IMA-THD32 (TYPE 1) 5.9 – 8.3 (148.6 – 210.6) IMM32 IMA-TDH32 (TYPE 4X) 5.9 – 16.2 (148.6 – 410.6) IMM32 IMA-TDH65 (TYPE 4X) 7.6 – 10.1 (193.6 – 255.6) IMM65 Extended Rotary Handle Dimensions in(mm) A Dimensions in (mm) A B C D IMM16 2.99 (76) 1.77 (45) 3.94 (100) 1.77 (45) IMM32 3.86 (98) 1.77 (45) 3.82 (97) 1.77 (45 IMM65 6.18 (157) 2.13 (54) 4.92 (125) 4.50 (114) B C D A Manual Motor Protector Dimensions in(mm) ®

RkJQdWJsaXNoZXIy NDU4NzI=