Factorymation Spring 2024 Catalog
To Order Call 1.800.972.0436 or Visit factorymation.com www.factorymation.com/motorcontrols MOTOR CONTROLS 76 General Specifications IMCxxx-07S IMCxxx-09S IMCxxx-12S IMCxxx-16S IMCxxx-25S General Purpose Rating (A) 18 20 22 22 32 Rated Operational Voltage (V) 12 to 690 Rated Insulation Voltage (V) UL/CSA: 600, IEC/VDE 0660: 690 Rated Impulse Voltage IEC60947-1 (V) 4000 Rated Operating Frequency (Hz) 25 to 400 Degree of Protection IP20 Vibration Resistance (5 to 200Hz) Contactor Open (g) 2 Contactor Closed at Coil (g) 4 Mechanical Endurance (Million ops) 10 (AC Coil) / 12 (DC Coil) 3 (AC Coil) Electrical Endurance (Million ops) 1.4 1.3 1.2 1 0.6 Shock Resistance (1/2 Sin Wave = 11ms) Contactor Open (g) 6 6 6 6 6 Contactor Closed at Coil (g) 10 10 10 10 10 Terminal Capacity Main Contacts (AWG) 1 or 2 x (18 to 12) 1 or 2 x (18 to 12) 1 or 2 x (18 to 12) 1 or 2 x (18 to 12) 1 or 2 x (18 to 10) Screw Driver Phillips #2 Phillips #2 Phillips #2 Phillips #2 Phillips #2 Tightening Torque (lb-in) 10 10 10 10 13 Environmental Conditions Ambient Temperature Storage: -67 to 176°F (-55 to 80°C), Operating: -4 to 140°F (-20 to 60°C) Climatic Withstand According to IEC 60680-2 Pollution Degree 3 Mounting 35mm DIN-rail Acc. DIN EN 50 022 Weight (lb) 0.42 0.42 0.42 0.42 0.42 Control Circuit Ratings (AC/DC COIL) Standard Voltages 12 to 660 (60Hz) Coil Operating Limits Monofrequency Coils (NO LOAD) (V) 0.85 to 1.1 Pick-up (V) 0.40 to 0.76 (AC-60Hz) / 0.40 to 0.70 (DC) Drop-out (V) 0.25 to 0.65 (AC-60Hz) / 0.15 to 0.40 (DC) Coil Consumption (Single coils) Sealed (VA) 2.5 to 3.5 2.5 to 3.5 2.5 to 3.5 2.5 to 3.5 10.8 to 13.2 Inrush (VA) 35 35 35 35 72 Power Factor Closed Cos Φ 0.28 0.28 0.28 0.28 0.32 Opened Cos Φ 0.85 0.85 0.85 0.85 0.93 Operating Time Coil Energization - N.O. (ms) 8 to 20 (AC-60Hz) / 10 to 20 (DC) 13 to 16 (AC-60Hz) Coil De-energization - N.O. (ms) 5 to 15 (AC-60Hz) / 2 to 8 (DC) 13.5 to 17 (AC-60Hz) General Specifications IMOL Standards IEC 60947-1 / 60947-4-1, UL 508; CSA C.22.2/14; VDE 0660/102 Number of Poles 3 Rated Operation & Insulation Voltage [V] UL/CSA: 600, IEC 60947-4-1: 690 Rated Impulse Voltage, Uimp [kV] 6 Tripping Class 10 Phase Failure Sensitivity Yes Current Direct Yes Alternating [Hz] Up to 400 Shock Resistance (IEC 60068-2-27; 1/2 sine wave) [g/ms] 10/11 Power Terminals IP Rating IP10 Main Terminals Capacity Cross/Slotted Combination Stranded / Solid (UL/CSA) [AWG] 14 - 6 Tightening Torque [lb-in] 20 Environmental Conditions Ambient Temperature Storage: -58 to 176°F (-50 to 80°C), Operating: -4 to 158°C (-20 to 70°C) Pollution Degree 3 Higher Value of Setting Range 3 Weight [lb] 0.33 Auxiliary Contacts Specifications Front Auxiliary Contact 1 NO / 1 NC Rated Auxiliary Contacts AC-14/15 24V:4A, 60V:3.5A, 125V:3A, 230V:2A, 400V:1.5A, 500V:0.5A, 690V:0.3A DC-13/14 24V:1A, 60V:0.5A, 110V:0.25A, 220V:0.1A UL/CSA C600 ; R300 Rated Thermal Current [A] 6 Short Circuit Protection (Time-delay Fuse ) [A] 6 Auxiliary Terminals Capacity [AWG] 16 - 12 Tightening Torque [lb-in] 13.3 Miniature Contactor Specifications Miniature Contactors & Overloads (cont’d) Miniature Overload Specifications ®
Made with FlippingBook
RkJQdWJsaXNoZXIy NDU4NzI=