Medium Voltage Motors and Soft Starters

Medium Voltage

Motors and Soft

Starters

Can’t find what you are looking for? Call

1-800-ASK-4WEG

(275-4934)

Data subject to change without notice.

A-251

Standard Features:

Voltage: 2300/4160V

Frequency: 60Hz

1.15SF at D.O.L. starting and safe area

Insulation Class F

VPI Impregnation

Class B Temperature Rise @ 1.00SF

Class F Temperature Rise @ 1.15SF

Aluminum Rotor (except where otherwise

indicated)

S1 Continuous Duty

TEFC

IP55 Protection Degree

F1 Mounting

Field conversion from F1 to F2 mounting

available for all motors 250HP and above

D.O.L. Starting

Direct coupling

Direction of Rotation:

CW for 2P motors (250HP and above)

Dual for 2P (200HP), 4P and 6P motors

Altitude: 3300 f.a.s.l.

Ambient temperature: 40ºC

NEMA Premium

®

Efficiency (250HP and above)

Grease lubricated antifriction (ball) bearings

100,000hs L10 bearings lifetime

Final Color: Blue (RAL 5009)

NEMA Type I main terminal box (loose leads)

Automatic grease relief

Grounding lugs on both sides of the frame

4140 Steel Shaft

36 Months warranty from manufacturing date

Standard Accessories:

RTD Pt100 Temperature Detectors

(02 per phase and 01 per bearing)

Space Heater, 120V

Provision (flat surface) for vibration sensors

Provision for dowel pins

Severe Duty Features:

Most relevant features of IEEE 841

Vibration level as per IEEE 841

Stainless Steel extended grease tubes

INPRO/SEAL on DE and NDE sides

0.005” feet flatness

Automatic threaded T-drains

(stainless steel)

Tropicalization

IEEE 841 Test reports

V.F.D. Operation Features:

1.00SF at V.F.D. Operation

Class B Temperature Rise @ 1.00SF

Suitable for V.F.D. Operation

10:1 VT with Class B temperature rise

2:1 CT with Class F temperature rise

Electrically Insulated N.D.E. bearing housing

Helwig Shaft Grounding brush

(Add-on Modification)

Note: A method of reducing common mode

voltages from motor terminals must be utilized.

Hazardous Area Features:

1.00SF at Hazardous Area

Class B Temperature Rise @ 1.00SF

CSA Certification: Class I, Div. 2,

Gr. A, B, C and D, T3

(Except 600HP 6P – Safe Area only)

Non-sparking external fan

Add-on Modifications from Stock

Note: For Add-on modifications, see page A253.

TEFC SEVERE DUTY MV MOTORS

Note: Special attention to Reciprocating Compressors applications where the motor design must be evaluated and confirmed in a case by case basis.