EDP11 - ENGINEERED DRIVE PANEL

Enclosed VFD Panel - NEMA 12 Enclosure (no By-Pass)

Motor

Voltage

ND / VT1

HD / CT1

Catalog

Number

Braking

Transistor

Drive

Frame

Size

Enclosure

Frame

Size

4

Dimensions

(in.)

HxWxD

7

Approx.

Weight

(lbs.)

7

List

Price

Multiplier

Motor

HP

2

Drive

Amps

3

Motor

HP

2

Drive

Amps

3

230 Vac

Input Power Supply: Three-Phase 220-240 Vac with Dynamic Braking Transistor

2

7.0

1 1/2

5.5

EDP11S007DN12

Yes

A

ED1

24 x 20 x 11.5

36

$6,690

V1

3

10

2

8.0

EDP11S010DN12

Yes

A

ED1

24 x 20 x 11.5

36

$6,756

V1

5

13

3

11

EDP11S013DN12

Yes

A

ED1

24 x 20 x 11.5

41

$6,855

V1

5

16

5

13

EDP11S016DN12

Yes

A

ED1

24 x 20 x 11.5

42

$7,123

V1

7 1/2

24

7 1/2

20

EDP11S024DN12

Yes

B

ED1

24 x 20 x 11.5

56

$7,664

V1

10

28

10

24

EDP11S028DN12

Yes

B

ED1

24 x 20 x 11.5

56

$8,408

V1

10

33.5

10

28

EDP11S033DN12

Yes

B

ED1

24 x 20 x 11.5

56

$9,108

V1

15

45

15

36

EDP11S045DN12

Yes

C

ED2

30 x 24 x 14

88

$10,214

V1

20

54

20

45

EDP11S054DN12

Yes

C

ED2

30 x 24 x 14

90

$11,491

V1

25

70

20

56

EDP11S070DN12

Yes

C

ED2

30 x 24 x 14

100

$12,162

V1

30

86

25

70

EDP11S086DN12

Yes

D

ED3

36 x 30 x 14

230

$14,321

V1

40

105

30

86

EDP11S105DN12

Yes

D

ED3

36 x 30 x 14

240

$17,164

V1

50

142

40

115

EDP11S142DN12

No

E

5

ED4

48 x 30 x 17.5

300

$19,793

V1

60

180

50

142

EDP11S180DN12

No

E

5

ED4

48 x 30 x 17.5

300

$25,116

V1

75

211

60

180

EDP11S211DN12

No

E

5

ED4

48 x 30 x 17.5

300

$28,326

V1

460 Vac

Input Power Supply: Three-Phase 460-480 Vac with Dynamic Braking Transistor

2

3.6

2

3.6

EDP11S003GN12

Yes

A

ED1

24 x 20 x 11.5

36

$6,510

V1

3

5.0

3

5.0

EDP11S005GN12

Yes

A

ED1

24 x 20 x 11.5

36

$6,626

V1

5

7.0

3

5.5

EDP11S007GN12

Yes

A

ED1

24 x 20 x 11.5

41

$6,690

V1

7 1/2

10

5

10

EDP11S010GN12

Yes

A

ED1

24 x 20 x 11.5

42

$6,756

V1

10

13.5

7 1/2

11

EDP11S013GN12

Yes

A

ED1

24 x 20 x 11.5

42

$6,855

V1

10

17

10

13.5

EDP11S017GN12

Yes

B

ED1

24 x 20 x 11.5

56

$7,269

V1

15

24

10

19

EDP11S024GN12

Yes

B

ED1

24 x 20 x 11.5

56

$7,821

V1

20

31

15

25

EDP11S031GN12

Yes

B

ED1

24 x 20 x 11.5

56

$8,580

V1

25

38

20

33

EDP11S038GN12

Yes

C

ED2

30 x 24 x 14

90

$9,293

V1

30

45

25

38

EDP11S045GN12

Yes

C

ED2

30 x 24 x 14

104

$10,422

V1

40

58.5

30

47

EDP11S058GN12

Yes

C

ED2

30 x 24 x 14

110

$12,026

V1

50/60

70.5

40

61

EDP11S070GN12

Yes

D

ED3

36 x 30 x 14

240

$12,729

V1

75

88

50

73

EDP11S088GN12

Yes

D

ED3

36 x 30 x 14

245

$14,988

V1

75

105

75

88

EDP11S105GN12

No

E

5

ED4

48 x 30 x 17.5

300

$17,964

V1

100/125 142

75

115

EDP11S142GN12

No

E

5

ED4

48 x 30 x 17.5

300

$20,715

V1

150

180

100

142

EDP11S180GN12

No

E

5

ED4

48 x 30 x 17.5

300

$26,286

V1

175

211

125

180

EDP11S211GN12

No

E

5

ED4

48 x 30 x 17.5

300

$29,645

V1

200

242

150

211

EDP11S242GN12

No

F

5

ED6

83 x 32 x 37

700

$40,755

V1

250

312

200

242

EDP11S312GN12

No

F

5

ED6

83 x 32 x 37

720

$45,114

V1

300

370

250

312

EDP11S370GN12

No

F

5

ED6

83 x 32 x 37

750

$47,743

V1

400

477

300

370

EDP11S477GN12

No

F

5

ED6

83 x 32 x 37

775

$54,585

V1

450

515

400

477

EDP11S515GN12

No

G

5

ED8

83 x 56 x 37

1100

$66,023

V1

500

601

450

515

EDP11S601GN12

No

G

5

ED8

83 x 56 x 37

1120

$71,875

V1

600

720

500

560

EDP11S720GN12

No

G

6

ED8

83 x 56 x 37

1150

$88,556

V1

Notes:

1) CT = Constant Torque, 150% overload / 60 sec.; VT = Variable Torque (Quadratic Load), 110% overload / 60 sec.

2) “HP” rating based on “average FLA values”. Use as a guide only.

3) Motor FLA may vary with speed and manufacturer. ALWAYS compare motor FLA to Nominal AMPS of drive.

4) ED1 - ED5 enclosures are non-ventilated and wall-mounted; ED6 - ED9 enclosures are ventilated and floor mounted.

5) Maximum 45°C ambient temperature without derating

6) Maximum 40°C ambient temperature without derating

7) Dimensions and weights are for estimating purposes only. Only use “AS BUILT” drawings for construction.

For other technical data please refer to WEG product manual.