Electrical Data

Electrical Data

B-34

Data subject to change without notice.

www.weg.net

Output

Frame

Full Load Torque

(ft.lb)

Locked

Rotor

Current

Locked Rotor

Torque Tl/Tn

Break-down

Torque Tb/Tn

Inertia J (lb-ft2)

Allowable

locked rotor

time (s)

Weight (lb)

Sound dB(A)

Service Factor

460 V

Rated speed

(rpm)

% of full load

Full load

current In (A)

Efficiency

Power Factor

HP kW

Code Il/In

Hot

Cold

50 75 100 50 75 100

50 37

324/6JM 73.0 F 6.2 2.2

2.3

5.75

23 51 584 78.0 1.25 3550 93.0 93.0 93.0 0.83 0.87 0.89 56.1

324/6JM 146 G 6.2 2.3

2.7

9.16

15 33 536 66.0 1.25 1775 93.0 94.1 94.5 0.66 0.77 0.83 59.2

364/5JM 220 G 6.4 2.0

2.4

32.4

18 40 869 66.0 1.25 1180 93.6 94.1 94.1 0.74 0.83 0.86 57.4

60 45

364/5JM 87.3 G 6.6 2.0

2.6

10.6

14 31 825 79.0 1.25 3560 91.7 93.0 93.6 0.81 0.88 0.90 67.0

364/5JM 175 G 6.6 2.4

2.6

22.4

15 33 869 67.0 1.25 1775 94.1 94.5 95.0 0.75 0.83 0.87 68.3

75 55

364/5JM 109 G 6.7 2.0

2.6

11.9

10 22 847 79.0 1.25 3555 92.4 93.6 93.6 0.83 0.88 0.90 81.9

364/5JM 219 G 6.4 2.4

2.6

23.3

14 31 919 67.0 1.25 1775 94.5 95.0 95.4 0.73 0.82 0.86 84.1

Close-Coupled Pump - JM - Three Phase - TEFC - Cast Iron -