Enclosed Motor Controls
Enclosed Motor
Controls
A-330
Data subject to change without notice.
www.weg.netMedium Voltage Starters
SSW7000C
Standard Features:
• Motor voltage: 2.3kV, 4.16kV
• Power: 400 hp to 3500 hp
• Protection Degree : NEMA12, IP 41
• Operating interface (HMI) with graphic LCD
• Real time clock
• Main and bypass vacuum contactors
• Medium voltage fuses
• Power and control insulated by fiber optics
• Soft PLC Function
• License Free programming software SuperDrive
and WLP
• Motor thermal protection - PT100 (accessory),
8 Channels
• Ground Fault Protection - standard
• 5 start modes
• Network communication boards (accessories):
DeviceNet, Profibus-DP, Ethernet and Modbus,
RS-232 or RS-485
• Flash Memory Module (accessory)
Advantages:
• Flexible Torque control
• Overload capacity of 400% for 20 s. (2x / hour
duty cycle)
• Management of Demand restrictions by the
electric company
• Bumpless starting
• Motor protection
• Mechanical wear reduction
• Handles lower inrush current limitations of
power supply
Special Features:
• Clean Assembly with easy accessibility to all
components
• Flexible Torque Control (FTC), by employing torque
estimation using vector control principle and
measurement of input voltage, output voltage
and output current. This provides more accurate
torque set-points, compared to estimating torque
values only via current measurement.
• Active Protection offers complete motor protection
in DOL START and RUN mode. This eliminates
need for any expensive motor protection relays for
backup protection.
• Optimized heat-sink design for balanced, compact
cooling
• Power stacks are light weight, independent phase
modules for ease of handling
• Ground Fault protection is standard
• Flexible Thermal Class Curve setup & selection that eliminates
need for third party expensive protection relays
• Soft PLC function with license-free software
• Nickel plated bus bars and bus-stub connections
provide corrosion resistance and
ensure proper electrical connection
• Power connection terminals for TOP or BOTTOM
motor connection
• Operator Interface (keypad, parameter setup) is
identical to that of WEG’s low voltage starter
product line
Certifications